Mechanical Seals in Submersible Pumps
2020-2-21 · A pump coupling was replaced to eliminate high vibration. 14 months later, the pump's mechanical seal (single seal arrangement) failed, resulting in a fire ignited by jet fuel contacting the hot bearing housing. The equipment and property were damaged. The incident had the potential for injury and environmental impact.